Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
1.
The Korean Journal of Parasitology ; : 163-172, 2022.
Article in English | WPRIM | ID: wpr-939142

ABSTRACT

Kinesin-13 (Kin-13), a depolymerizer of microtubule (MT), has been known to affect the length of Giardia. Giardia Kin-13 (GlKin-13) was localized to axoneme, flagellar tips, and centrosomes, where phosphorylated forms of Giardia polo-like kinase (GlPLK) were distributed. We observed the interaction between GlKin-13 and GlPLK via co-immunoprecipitation using transgenic Giardia cells expressing Myc-tagged GlKin-13, hemagglutinin-tagged GlPLK, and in vitro-synthesized GlKin-13 and GlPLK proteins. In vitro-synthesized GlPLK was demonstrated to auto-phosphorylate and phosphorylate GlKin-13 upon incubation with [γ-32P]ATP. Morpholino-mediated depletion of both GlKin-13 and GlPLK caused an extension of flagella and a decreased volume of median bodies in Giardia trophozoites. Our results suggest that GlPLK plays a pertinent role in formation of flagella and median bodies by modulating MT depolymerizing activity of GlKin-13.

2.
Korean Journal of Radiology ; : 1708-1718, 2021.
Article in English | WPRIM | ID: wpr-902484

ABSTRACT

Objective@#The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3–4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). @*Materials and Methods@#Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. @*Results@#All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). @*Conclusion@#In the phantom experiments, the ESIONs with 3–4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

3.
Korean Journal of Radiology ; : 706-713, 2021.
Article in English | WPRIM | ID: wpr-902478

ABSTRACT

Objective@#To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. @*Materials and Methods@#A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis.Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1–10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. @*Results@#In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5–43.5) and 21.4 (17.9–192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2–29.5) and 13.6 (10.3–30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6–17.7) and 8.0 (1.8–170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). @*Conclusion@#Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.

4.
Korean Journal of Radiology ; : 688-696, 2021.
Article in English | WPRIM | ID: wpr-902463

ABSTRACT

Objective@#To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS). @*Materials and Methods@#The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods.Bland-Altman plots were used to evaluate the agreement between the measurements. @*Results@#Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 ㎣ ; 95% confidence interval [CI], 4.9–24.3 ㎣ ); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 ㎣ ; 95% CI, -9.1–7.7 ㎣ ). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 ㎟ ; 95% CI, 0.89–1.25 ㎟ ) but not in the larger lumen area group (mean of difference, -0.07 ㎟ ; 95% CI, -0.22–0.08 ㎟ ). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 ㎟ ; 95% CI, 0.27–0.65 ㎟ ) than in that of IVUS and SATM (1.53 ㎟ ; 95% CI, 1.27–1.79㎟ ). @*Conclusion@#SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.

5.
Korean Journal of Radiology ; : 1708-1718, 2021.
Article in English | WPRIM | ID: wpr-894780

ABSTRACT

Objective@#The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3–4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). @*Materials and Methods@#Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. @*Results@#All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). @*Conclusion@#In the phantom experiments, the ESIONs with 3–4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

6.
Korean Journal of Radiology ; : 706-713, 2021.
Article in English | WPRIM | ID: wpr-894774

ABSTRACT

Objective@#To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. @*Materials and Methods@#A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis.Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1–10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. @*Results@#In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5–43.5) and 21.4 (17.9–192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2–29.5) and 13.6 (10.3–30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6–17.7) and 8.0 (1.8–170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). @*Conclusion@#Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.

7.
Korean Journal of Radiology ; : 688-696, 2021.
Article in English | WPRIM | ID: wpr-894759

ABSTRACT

Objective@#To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS). @*Materials and Methods@#The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods.Bland-Altman plots were used to evaluate the agreement between the measurements. @*Results@#Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 ㎣ ; 95% confidence interval [CI], 4.9–24.3 ㎣ ); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 ㎣ ; 95% CI, -9.1–7.7 ㎣ ). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 ㎟ ; 95% CI, 0.89–1.25 ㎟ ) but not in the larger lumen area group (mean of difference, -0.07 ㎟ ; 95% CI, -0.22–0.08 ㎟ ). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 ㎟ ; 95% CI, 0.27–0.65 ㎟ ) than in that of IVUS and SATM (1.53 ㎟ ; 95% CI, 1.27–1.79㎟ ). @*Conclusion@#SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.

8.
Korean Journal of Radiology ; : 1918-1928, 2021.
Article in English | WPRIM | ID: wpr-918198

ABSTRACT

Objective@#With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. @*Materials and Methods@#We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). @*Results@#The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). @*Conclusion@#The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.

9.
Investigative Magnetic Resonance Imaging ; : 1-20, 2020.
Article | WPRIM | ID: wpr-835534

ABSTRACT

This document is the third part of the guidelines for the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by a Consensus Committee of the Korean Society of Cardiovascular Imaging (KOSCI) to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment, consisting of “What-to-See,” “How-To,” and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.

10.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 127-131, 2020.
Article | WPRIM | ID: wpr-835287

ABSTRACT

Background@#This study was conducted to evaluate the safety and efficacy of left atrial appendage (LAA) excision using a vascular stapler. @*Methods@#Fifty consecutive patients (mean age, 68±9 years) who underwent LAA excision using a vascular stapler during concomitant cardiac surgery were enrolled. In all patients, the excision site was evaluated using computed tomography at a median of 7 days (interquartile range, 5–13.3 days) postoperatively. The safety endpoint of this study was the occurrence of LAA excision-related events, which were defined as bleeding from the excision site that required reinforcement sutures or reoperation due to excision site bleeding. The efficacy endpoint was LAA excision failure, which was defined as a remnant LAA (a stump >1 cm in maximum length) or extravasation of radiocontrast dye. @*Results@#LAAs were excised using 60- and 45-mm vascular staplers in 49 patients and 1 patient, respectively. Reinforcement sutures were needed in 4 patients due to staple-line bleeding and in 4 patients due to bleeding of the surrounding tissues. No patient underwent reoperation due to staple-related bleeding. A remnant LAA was observed in 2 patients, while extravasation of radiocontrast dye was not observed in any patients. @*Conclusion@#LAA excision using a vascular stapler may be an effective technique for LAA exclusion. Delicate handling of the stapler device and LA tissue is required to prevent procedure- related complications.

11.
Journal of Pathology and Translational Medicine ; : 396-410, 2020.
Article | WPRIM | ID: wpr-834571

ABSTRACT

Background@#The definitive pathologic diagnosis of cardiac sarcoidosis requires observation of a granuloma in the myocardial tissue. It is common, however, to receive a “negative” report for a clinically probable case. We would like to advise pathologists and clinicians on how to interpret “negative” biopsies. @*Methods@#Our study samples were 27 endomyocardial biopsies from 25 patients, three cardiac transplantation and an autopsied heart with suspected cardiac sarcoidosis. Pathologic, radiologic, and clinical features were compared. @*Results@#The presence of micro-granulomas or increased histiocytic infiltration was always (6/6 or 100%) associated with fatty infiltration and confluent fibrosis, and they showed radiological features of sarcoidosis. Three of five cases (60%) with fatty change and confluent fibrosis were probable for cardiac sarcoidosis on radiology. When either confluent fibrosis or fatty change was present, one-third (3/9) were radiologically probable for cardiac sarcoidosis. We interpreted cases with micro-granuloma as positive for cardiac sarcoidosis (five of 25, 20%). Cases with both confluent fibrosis and fatty change were interpreted as probable for cardiac sarcoidosis (seven of 25, 28%). Another 13 cases, including eight cases with either confluent fibrosis or fatty change, were interpreted as low probability based on endomyocardial biopsy. @*Conclusions@#The presence of micro-granuloma could be an evidence for positive diagnosis of cardiac sarcoidosis. Presence of both confluent fibrosis and fatty change is necessary for probable cardiac sarcoidosis in the absence of granuloma. Either of confluent fibrosis or fatty change may be an indirect pathological evidence but they are interpreted as nonspecific findings.

12.
Korean Journal of Radiology ; : 1165-1177, 2020.
Article | WPRIM | ID: wpr-833579

ABSTRACT

Objective@#To assess the feasibility of applying a deep learning-based denoising technique to coronary CT angiography (CCTA) along with iterative reconstruction for additional noise reduction. @*Materials and Methods@#We retrospectively enrolled 82 consecutive patients (male:female = 60:22; mean age, 67.0 ± 10.8 years) who had undergone both CCTA and invasive coronary artery angiography from March 2017 to June 2018. All included patients underwent CCTA with iterative reconstruction (ADMIRE level 3, Siemens Healthineers). We developed a deep learning based denoising technique (ClariCT.AI, ClariPI), which was based on a modified U-net type convolutional neural net model designed to predict the possible occurrence of low-dose noise in the originals. Denoised images were obtained by subtracting the predicted noise from the originals. Image noise, CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively calculated. The edge rise distance (ERD) was measured as an indicator of image sharpness. Two blinded readers subjectively graded the image quality using a 5-point scale. Diagnostic performance of the CCTA was evaluated based on the presence or absence of significant stenosis (≥ 50% lumen reduction). @*Results@#Objective image qualities (original vs. denoised: image noise, 67.22 ± 25.74 vs. 52.64 ± 27.40; SNR [left main], 21.91 ± 6.38 vs. 30.35 ± 10.46; CNR [left main], 23.24 ± 6.52 vs. 31.93 ± 10.72; all p < 0.001) and subjective image quality (2.45 ± 0.62 vs. 3.65 ± 0.60, p < 0.001) improved significantly in the denoised images. The average ERDs of the denoised images were significantly smaller than those of originals (0.98 ± 0.08 vs. 0.09 ± 0.08, p < 0.001). With regard to diagnostic accuracy, no significant differences were observed among paired comparisons. @*Conclusion@#Application of the deep learning technique along with iterative reconstruction can enhance the noise reduction performance with a significant improvement in objective and subjective image qualities of CCTA images.

13.
Journal of the Korean Radiological Society ; : 1529-1536, 2020.
Article in English | WPRIM | ID: wpr-832905

ABSTRACT

Invasive pulmonary aspergillosis (IPA) has been known to occur in immunocompromised patients, but has been rarely reported in immunocompetent patients. In immunocompetent patients, pulmonary fungal infections are not initially considered. This results in diagnosis and treatment delays, as well as poor prognosis. We report a case and serial CT findings of IPA in an immunocompetent 29-year-old male after congenital heart disease surgery.

14.
Korean Journal of Radiology ; : 268-279, 2020.
Article in English | WPRIM | ID: wpr-810987

ABSTRACT

OBJECTIVE: To determine the most valuable cardiac magnetic resonance feature tracking (CMR-FT) parameters for evaluating aortic stenosis (AS) and determine whether they can predict the prognosis in asymptomatic AS patients with preserved ejection fraction (pEF).MATERIALS AND METHODS: A prospective cohort of 123 moderate to severe AS patients (60 males, 68.6 ± 9.2 years) and 32 control subjects (14 males, 67.9 ± 4.4 years) underwent echocardiography and 3T CMR imaging from 2011–2015. CMR cine images were analyzed using CMR-FT to assess the left ventricular radial, circumferential, and longitudinal peak strain (PS) in 2- and 3-dimensions. The primary endpoints were clinical cardiac events (CCEs), including cardiac death, heart failure, and AS-associated symptom development. For statistical analysis, logistic regression and log-rank tests were used.RESULTS: Global PSs differed between AS patients and controls and between severe and moderate AS patients (p < 0.05). Two-dimensional (2D) global radial and longitudinal PSs changed gradually with the severity of AS groups (p < 0.001). Twenty-two of 67 asymptomatic AS patients with pEF experienced CCEs during the follow-up (median: 31.1 months). 2D global longitudinal PS (GLPS) was the single risk factor for CCE (p = 0.017). The relative risk for CCE was 3.9 (p = 0.016, 95% confidence interval: 1.2–11.9) based on 2D GLPS with a cutoff of −17.9% according to receiver operating characteristic curve analysis. Survival analysis demonstrated that asymptomatic AS patients with pEF having impaired 2D GLPS experienced worse event-free survival than the others (p = 0.041).CONCLUSION: 2D global longitudinal and radial PSs may reflect cardiac dysfunction according to the degree of AS. 2D GLPS might be a prognostic predictor of CCEs in asymptomatic AS patients with pEF.


Subject(s)
Humans , Male , Aortic Valve Stenosis , Cohort Studies , Death , Disease-Free Survival , Echocardiography , Follow-Up Studies , Heart Failure , Logistic Models , Prognosis , Prospective Studies , Risk Factors , ROC Curve
15.
Investigative Magnetic Resonance Imaging ; : 296-315, 2019.
Article in English | WPRIM | ID: wpr-785884

ABSTRACT

Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.


Subject(s)
Cardiovascular Diseases , Commerce , Exercise Test , Heart , Hope , Magnetic Resonance Imaging , Public Health
16.
Investigative Magnetic Resonance Imaging ; : 316-327, 2019.
Article in English | WPRIM | ID: wpr-785883

ABSTRACT

Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technology advances and the expanded national insurance coverage of these tests. For improved patient care, it is crucial not only that CMR images are properly acquired but that they are accurately interpreted by well-trained personnel. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology (KSR). KOSCI has also created a formal Committee on CMR Guidelines to write updated practices. The members of this Committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.


Subject(s)
Angiography , Heart , Insurance Coverage , Korea , Magnetic Resonance Imaging , Patient Care
17.
Investigative Magnetic Resonance Imaging ; : 395-400, 2019.
Article in English | WPRIM | ID: wpr-785873

ABSTRACT

Acromegaly is a rare endocrine disorder caused by excessive secretion of the growth hormone. There is a wide range of clinical manifestations from somatic symptoms to respiratory or cardiac failure. Among them, cardiovascular involvement is a leading cause of morbidity and mortality. There are relatively few cases reporting cardiac magnetic resonance imaging (CMR) findings of cardiomyopathy in patients with acromegaly. Thus, we report a case of acromegaly showing dilated cardiomyopathy focusing on the findings of CMR.


Subject(s)
Humans , Acromegaly , Cardiomyopathies , Cardiomyopathy, Dilated , Growth Hormone , Heart Failure , Magnetic Resonance Imaging , Mortality
18.
Korean Journal of Radiology ; : 1562-1582, 2019.
Article in English | WPRIM | ID: wpr-786373

ABSTRACT

This document is the third part of the guidelines for the protocol, the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by the Consensus Committee of the Korean Society of Cardiovascular Imaging to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment consisting of “What-to-See,” “How-To,” and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.


Subject(s)
Consensus , Gadolinium , Hope , Magnetic Resonance Imaging , Perfusion
19.
Korean Journal of Radiology ; : 719-728, 2019.
Article in English | WPRIM | ID: wpr-741460

ABSTRACT

OBJECTIVE: To investigate the diagnostic validity of coronary computed tomography angiography (cCTA) in vasospastic angina (VA) and factors associated with discrepant results between invasive coronary angiography with the ergonovine provocation test (iCAG-EPT) and cCTA. MATERIALS AND METHODS: Of the 1397 patients diagnosed with VA from 2006 to 2016, 33 patients (75 lesions) with available cCTA data from within 6 months before iCAG-EPT were included. The severity of spasm (% diameter stenosis [%DS]) on iCAG-EPT and cCTA was assessed, and the difference in %DS (Δ%DS) was calculated. Δ%DS was compared after classifying the lesions according to pre-cCTA-administered sublingual nitroglycerin (SL-NG) or beta-blockers. The lesions were further categorized with %DS ≥ 50% on iCAG-EPT or cCTA defined as a significant spasm, and the diagnostic performance of cCTA on identifying significant spasm relative to iCAG-EPT was assessed. RESULTS: Compared to lesions without SL-NG treatment, those with SL-NG treatment showed a higher Δ%DS (39.2% vs. 22.1%, p = 0.002). However, there was no difference in Δ%DS with or without beta-blocker treatment (35.1% vs. 32.6%, p = 0.643). The significant difference in Δ%DS associated with SL-NG was more prominent in patients who were aged < 60 years, were male, had body mass index < 25 kg/m2, and had no history of hypertension, diabetes, or dyslipidemia. Based on iCAG-EPT as the reference, the per-lesion-based sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of cCTA for VA diagnosis were 7.5%, 94.0%, 60.0%, 47.1%, and 48.0%, respectively. CONCLUSION: For patients with clinically suspected VA, confirmation with iCAG-EPT needs to be considered without completely excluding the diagnosis of VA simply based on cCTA results, although further prospective studies are required for confirmation.


Subject(s)
Humans , Male , Angina Pectoris, Variant , Angiography , Body Mass Index , Constriction, Pathologic , Coronary Angiography , Diagnosis , Dyslipidemias , Ergonovine , Hypertension , Nitroglycerin , Prospective Studies , Sensitivity and Specificity , Spasm
20.
Korean Journal of Radiology ; : 1313-1333, 2019.
Article in English | WPRIM | ID: wpr-760306

ABSTRACT

Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.


Subject(s)
Cardiovascular Diseases , Commerce , Exercise Test , Heart , Hope , Magnetic Resonance Imaging , Public Health
SELECTION OF CITATIONS
SEARCH DETAIL